Difference between revisions of "Neutron scattering in lead shielding"
Jump to navigation
Jump to search
(Created page with "go back JB_Analysis go back JB_Analysis") |
|||
(12 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | go back [[ | + | go back [[MCNP simulations]] |
+ | Source neutrons are generated with MCNP-POLIMI CF252 SF generator. The detector is 1.25 meters from the source and the shielding geometry is shown below. The X-axis in the histogram is a distance between 2 points, namely: p1) Linearly extrapolating the neutron's initial direction of travel to intersect with the plane of the detector, and p2) the "actual" location in which the neutron deposited >=0.25 MeV of energy into the scintillator. The result is that on average the shielding scatters the neutrons by only 1". | ||
+ | [[File:DetGeom.png|600px]] | ||
+ | [[File:NDeflection.png|770px]] | ||
Line 10: | Line 13: | ||
− | go back [[ | + | go back [[MCNP simulations]] |
Latest revision as of 22:47, 8 March 2017
go back MCNP simulations
Source neutrons are generated with MCNP-POLIMI CF252 SF generator. The detector is 1.25 meters from the source and the shielding geometry is shown below. The X-axis in the histogram is a distance between 2 points, namely: p1) Linearly extrapolating the neutron's initial direction of travel to intersect with the plane of the detector, and p2) the "actual" location in which the neutron deposited >=0.25 MeV of energy into the scintillator. The result is that on average the shielding scatters the neutrons by only 1".
go back MCNP simulations