Difference between revisions of "11-10-2016"

From New IAC Wiki
Jump to navigation Jump to search
Line 44: Line 44:
 
|-
 
|-
 
|}
 
|}
 +
 +
 +
Source tests
 +
 +
{| border="1"
 +
| Run # ||D90 n Rate (Counts/pulse)|| Configuration
 +
|-
 +
|5431 || -|| Cf source, set thresholds to 40 mV, 800 Hz cosmic rate on D90, All HV's are 1500 except for D30 and the trigger
 +
|-
 +
|}
 +
  
 
[[2nCor_44#Run_Plan]]
 
[[2nCor_44#Run_Plan]]

Revision as of 02:36, 11 November 2016

Horizontal accelerator side collimator 7 mm, horizontal cell side 19 mm.

Run # D90 n Rate (Counts/pulse) Configuration
5413 - 11.2 MeV , 2 ns FWHM pulse width , 1.4 A Peak , 180.4 Hz , Radiator 1" Al., Empty target, discriminator thresh 30 mV, All detectors at -1700 V
5414 - 11.2 MeV , 2 ns pulse width , 1.4 A Peak , 180.4 Hz , Radiator 1" Al., Al target , discriminator thresh 30 mV, All detectors at -1700 V
5415 - 11.2 MeV , 2 ns pulse width , 1.4 A Peak , 180.4 Hz , Radiator 1" Al., Empty target, discriminator thresh 30 mV, All detectors at -1700 V
5416 - 11.2 MeV , 2 ns pulse width , 1.4 A Peak , 180.4 Hz , Radiator 1" Al., Thorium target, discriminator thresh 30 mV, All detectors at -1700 V
5417 - 11.2 MeV , 2 ns pulse width , 0.2 A Peak , 180.4 Hz , Radiator 1" Al., Thorium target, discriminator thresh 30 mV, All detectors at -1700 V
5418 - 11.2 MeV , 2 ns pulse width , 0.2 A Peak , 180.4 Hz , Radiator 1" Al., D20 target, discriminator thresh 30 mV, All detectors at -1700 V
5419 - 11.2 MeV , 2 ns pulse width , 0.2 A Peak , 180.4 Hz , Radiator 1" Al., D20 target', discriminator thresh 30 mV, All detectors at -1500 V (later parts have HV =-1400 and D30 & D330)
5420 - 11.2 MeV , 2 ns pulse width , 0.2 A Peak , 180.4 Hz , Radiator 1" Al., D20 target', discriminator thresh 30 mV, All detectors at -1500 V except D30 & D330 which are at HV =-1400
5421 - 11.2 MeV , 2 ns pulse width , 0.2 A Peak , 180.4 Hz , Radiator 1" Al., D20 target', discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450
5422 - 11.2 MeV , 2 ns pulse width , 0.2 A Peak , 180.4 Hz , Radiator 1" Al., MT, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450
5423 - 11.2 MeV , 2 ns pulse width , 0.5 A Peak , 180.4 Hz , Radiator 1" Al., MT, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450
5424 - 11.2 MeV , 2 ns pulse width , 0.5 A Peak , 180.4 Hz , Radiator 1" Al., Al, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450
5425 - 11.2 MeV , 2 ns pulse width , 0.5 A Peak , 180.4 Hz , Radiator 1" Al., Al target, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450, replaced lead beam dump with Aluminum, 8" center + 4" radially out (ie double brick near center and single brick layer on outside)
5426 - 10.5 MeV , 2 ns pulse width , 1.0 A Peak , 180.4 Hz , Radiator 1" Al., Al target, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450, replaced lead beam dump with Aluminum, 8" center + 4" radially out (ie double brick near center and single brick layer on outside)
5427 - 10.5 MeV , 2 ns pulse width , 1.0 A Peak , 180.4 Hz , Radiator 1" Al., Th target, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450, replaced lead beam dump with Aluminum, 8" center + 4" radially out (ie double brick near center and single brick layer on outside)
5428 - 10.5 MeV , 2 ns pulse width , 1.0 A Peak , 180.4 Hz , Radiator 1" Al., Th target, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450, replaced Aluminum beam dump with battleship iron blinders, plus shielded D330 from beam dump
5429 - 10.5 MeV , 2 ns pulse width , 0.5 A Peak , 180.4 Hz , Radiator 1" Al., Th target, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450, replaced Aluminum beam dump with battleship iron blinders, plus shielded D330 from beam dump
5430 - 10.5 MeV , 2 ns pulse width , 0.25 A Peak , 180.4 Hz , Radiator 1" Al., Th' target, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450, replaced Aluminum beam dump with battleship iron blinders, plus shielded D330 from beam dump
5431 - 10.5 MeV , 2 ns pulse width , 0.25 A Peak , 180.4 Hz , Radiator 1" Al., MT target, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450, replaced Aluminum beam dump with battleship iron blinders, plus shielded D330 from beam dump
5432 - 10.5 MeV , 2 ns pulse width , 1.0 A Peak , 180.4 Hz , Radiator 1" Al., MT target, discriminator thresh 30 mV, All detectors at -1500 V except D30 which is at HV =-1450, replaced Aluminum beam dump with battleship iron blinders, plus shielded D330 from beam dump


Source tests

Run # D90 n Rate (Counts/pulse) Configuration
5431 - Cf source, set thresholds to 40 mV, 800 Hz cosmic rate on D90, All HV's are 1500 except for D30 and the trigger


2nCor_44#Run_Plan