| |5308 || || 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''~0.5 mm x 7 cm x 4 mm Thorium'''  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain, [[File:Rate2nC_5308.png|40px]] | |5308 || || 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''~0.5 mm x 7 cm x 4 mm Thorium'''  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain, [[File:Rate2nC_5308.png|40px]] | ||
| |- | |- | ||
| − | |5312 || || 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''EMPTY'''  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain, Install 16" deep x24" wide x 14" high ALuminum photon''' beam dump'''.  Beam upstream side of dump is 37" from wall[[File: | + | |5312 || || 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''EMPTY'''  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain, Install 16" deep x24" wide x 14" high ALuminum photon''' beam dump'''.  Beam upstream side of dump is 37" from wall[[File:Rate2nC_5312.png|40px]] | 
| |- | |- | ||
| |530 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''~0.5 mm x 7 cm x 4 mm Th'''  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Installed 3rd collimator wall, D30 has NO thick lead curtain [[File:Rate2nC_5309.png|40px]] | |530 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''~0.5 mm x 7 cm x 4 mm Th'''  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Installed 3rd collimator wall, D30 has NO thick lead curtain [[File:Rate2nC_5309.png|40px]] | ||
Revision as of 17:25, 8 September 2016
Study forward detector gamma flash
with Pb curtains
Shielding & Beam dump impact on gamma flash
| Run # | D90 n Rate (Counts/pulse) | Configuration | 
| 5300 | 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is Empty  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,   | |
| 5301 | 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to '0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is Empty  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand, Installed 3rd collimator wall, removed line of site between D30 and cell wall collimator   | |
| 5305 | 11.1 MeV , 2 ns pulse width , 300 mA , 90 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is EMPTY  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain,   | |
| 5306 | 11.1 MeV , 2 ns pulse width , 300 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is EMPTY  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain,   | |
| 5307 | 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is EMPTY  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain,   | |
| 5308 | 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is ~0.5 mm x 7 cm x 4 mm Thorium  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain,   | |
| 5312 | 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is EMPTY  , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain, Install 16" deep x24" wide x 14" high ALuminum photon beam dump.  Beam upstream side of dump is 37" from wall   | |
| 530 | 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is ~0.5 mm x 7 cm x 4 mm Th , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Installed 3rd collimator wall, D30 has NO thick lead curtain 40px | 
Tuning impact on gamma flash
We set up a veto to create a signal that represented the second peak of the gamma flash in D270 & others. A veto pulse was created for the LED to prevent it from outputing a logic high during the first 20 ns after the beam pulse.
| Run # | D90 n Rate (Counts/pulse) | Configuration | 
| 5309 | 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is EMPTY , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain, Veto OUT40px | |
| 5310 | 11.1 MeV , 2 ns pulse width , 250 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is EMPTY , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Removed 3rd collimator wall, D30 has NO thick lead curtain, Veto IN40px | 