|5297 ||0.01768 || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.8 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is DU , D30 HV changed from -1700 to '''-1550V''', All other detectors at -1700 V,moved stand below pair spectrometer magnet, '''added 2 borated poly bricks to catch positrons and 4" unborated poly to catch electrons exiting pair spectrometer magnet''',[[File:Rate2nC_5297.png|40px]] | |5297 ||0.01768 || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.8 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is DU , D30 HV changed from -1700 to '''-1550V''', All other detectors at -1700 V,moved stand below pair spectrometer magnet, '''added 2 borated poly bricks to catch positrons and 4" unborated poly to catch electrons exiting pair spectrometer magnet''',[[File:Rate2nC_5297.png|40px]] | ||
|- | |- | ||
− | |5298 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.8 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is DU , D30 HV changed -1550V, All other detectors at -1700 V, '''removed pair spectrometer magnet, poly, and stand''',[[File:Rate2nC_5298.png|40px]] | + | |5298 || 0.0132|| 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.8 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is DU , D30 HV changed -1550V, All other detectors at -1700 V, '''removed pair spectrometer magnet, poly, and stand''',[[File:Rate2nC_5298.png|40px]] |
|- | |- | ||
− | |5299 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.8 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''Empty''' , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,[[File:Rate2nC_5299.png|40px]] | + | |5299 || 0.00743|| 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.8 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''Empty''' , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,[[File:Rate2nC_5299.png|40px]] |
+ | |- | ||
+ | |5300 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to '''0.2563 cm''', Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is Empty , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,[[File:Rate2nC_5300.png|40px]] | ||
+ | |- | ||
+ | |5301 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to '0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is Empty , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand, '''Installed 3rd collimator wall''', removed line of site between D30 and cell wall collimator [[File:Rate2nC_5301.png|40px]] | ||
+ | |- | ||
+ | |5302 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''DU''' , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Installed 3rd collimator wall, D30 has one 1/16" thick lead curtain [[File:Rate2nC_5302.png|40px]] | ||
+ | |- | ||
+ | |5303 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is DU , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Installed 3rd collimator wall, D30 has '''NO''' lead curtain [[File:Rate2nC_5303.png|40px]] | ||
+ | |- | ||
+ | |5304 || || 11.1 MeV , 2 ns pulse width , 450 mA , 200 Hz , Accelerator side collimator open to 0.2563 cm, Cell side collimator OPEN to 2 cm , radiator 3/4" IN , Target is '''~0.5 mm x 7 cm x 4 mm Th''' , D30 HV changed -1550V, All other detectors at -1700 V, removed pair spectrometer magnet, poly, and stand,Installed 3rd collimator wall, D30 has '''NO''' lead curtain, unplugged D225T to observe analog pulse during run , interlock trip ends run early[[File:Rate2nC_5304.png|40px]] | ||
|- | |- | ||
|} | |} | ||
− | + | ||
− | + | [[2nCor_44#Run_Plan]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Latest revision as of 22:45, 7 September 2016
No target collimator open
- Beam Conditions
- 11.1 MeV , 2 ns pulse width
- Detector HV
- =-1700 Volts on all detectors
DU cylinder target
- Beam Conditions
- 11.1 MeV , 2 ns pulse width
1” Al radiator, collimator slit open, HV -1700V,*Find lowest thresholds to run.