Difference between revisions of "Signal cable timing"

From New IAC Wiki
Jump to navigation Jump to search
Line 14: Line 14:
 
| Top  
 
| Top  
 
| D30T001  
 
| D30T001  
| +0    <!--Top delta t from D30T001-->
+
| +0 (be definition)     <!--Top delta t from D30T001-->
 
| rowspan="2" | +15  <!--Bottom minus top-->
 
| rowspan="2" | +15  <!--Bottom minus top-->
  

Revision as of 19:36, 17 August 2016

Detector PMT sig. cable [math]\Delta t[/math] relative to D30T001 [ns] PMT bot - PMT top
angle color
30 Red Top D30T001 +0 (be definition) +15
Bot D30B002 +15
90 Yellow Top D90T003 +1 ?
Bot D90B004 ?
150 Blue Top D150T005 +1 ?
Bot D150B006 ?
225 Wood Top D225T007 -3 ?
Bot D225B008 ?

Trigger plugged into patch panel 223A15 : -8 ns