Rerunning the GEANT simulation for a target of solo atoms of Carbon 12


Scattered Electron Momentum in Lab Frame
Figure 8a: The scattered electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.


Moller Electron Momentum in Lab Frame
Figure 8b: The Moller electron momentum distribution for 4E7 incident 11 GeV electrons in the Lab frame of reference.


These graphs show an offset based upon the density of the target material.

Density of target material

C=2.26 g/cm3

NH3=.86g/cm3

LH2=.07g/cm3

[math]\Longrightarrow[/math]The greater the density, the smaller the solid angle into which the Moller electron will scatter.